- LMQ3 MXS
- Switching-power-supply-circuit 开关电源电路Switching power supply circuit
- Nd-YAG-固体激光器电光调Q、倍频实验讲义 Nd:YAG 固体激光器电光调Q等实验相关操作流程(Nd:YAG solid laser
- merge_count 在一个数组中可以找出所有的逆序对数
- Dual_Video_Camera_PoC-master A prototype camera app for recording using both cameras in a single video(This application is a prototype to test the technical feasibility
- transfer_alignment-master 关于传递对准的MATLAB仿真源代码 包含卡尔曼滤波模型建立等(transfer
文件名称:OPEN-SWITCH-FAULTS-DETECTION-AND
-
所属分类:
- 标签属性:
- 上传时间:2013-01-01
-
文件大小:306.53kb
-
已下载:0次
-
提 供 者:
-
相关连接:无下载说明:别用迅雷下载,失败请重下,重下不扣分!
介绍说明--下载内容来自于网络,使用问题请自行百度
This paper proposes an open switch faults detection and localization algorithm for shunt three
phase active filter topology. It mainly details converter configuration and examines a simple and
reliable optimised fault diagnosis method. The con verter topology is based on classical three-leg
active power filter topology. A ne w fault diagnosis method is proposed, based on classical
currents measurements. It includes combinatory logic to analyse and validate error signals. A
Hysteresis Control is applied before and after fault detection, which avoids any controller
reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the
effectiveness of this method. -This paper proposes an open switch faults detection and localization algorithm for shunt three
phase active filter topology. It mainly details converter configuration and examines a simple and
reliable optimised fault diagnosis method. The con verter topology is based on classical three-leg
active power filter topology. A ne w fault diagnosis method is proposed, based on classical
currents measurements. It includes combinatory logic to analyse and validate error signals. A
Hysteresis Control is applied before and after fault detection, which avoids any controller
reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the
effectiveness of this method.
phase active filter topology. It mainly details converter configuration and examines a simple and
reliable optimised fault diagnosis method. The con verter topology is based on classical three-leg
active power filter topology. A ne w fault diagnosis method is proposed, based on classical
currents measurements. It includes combinatory logic to analyse and validate error signals. A
Hysteresis Control is applied before and after fault detection, which avoids any controller
reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the
effectiveness of this method. -This paper proposes an open switch faults detection and localization algorithm for shunt three
phase active filter topology. It mainly details converter configuration and examines a simple and
reliable optimised fault diagnosis method. The con verter topology is based on classical three-leg
active power filter topology. A ne w fault diagnosis method is proposed, based on classical
currents measurements. It includes combinatory logic to analyse and validate error signals. A
Hysteresis Control is applied before and after fault detection, which avoids any controller
reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the
effectiveness of this method.